Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of Biomedical Engineering ; (6): 460-467, 2019.
Article in Chinese | WPRIM | ID: wpr-774184

ABSTRACT

In order to quantitatively evaluate the performance of dry electrode for fabric surface bioelectricity, a set of active measuring devices that can simulate electrocardiosignal has been developed on the basis of passive system by our group. Five Ag/AgCl fabric dry electrodes were selected to test and evaluate the devices. The results show that the deviation ratios of peak time interval of the five electrodes are all less than 1%. The maximum voltage amplitude decay rate is 7.2%, and the noise amplitudes are lower than 0.004 mV. The variable coefficient of peak time offset is less than 8%. The variable coefficient of voltage amplitude is less than 2%. The variable coefficient of noise amplitude is less than 10%. Research shows the devices has good repeatability and stability in measuring the simulated electrocardiosignal. The active measuring devices proposed in this paper can provide a new method for performance evaluation and standard formulation of surface bioelectricity dry electrode.


Subject(s)
Electrodes , Textiles , Wearable Electronic Devices
2.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-586955

ABSTRACT

The portable dynamic electrocardiosignal data collector is the important part in the dynamic ECG analysis system.In this paper,the writer introduces the principle of intelligent data collector system,which takes microcontroller as core,and discusses the points of hardware design and the arithmatic of data pretreatment software.

3.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-591335

ABSTRACT

Objective There are many interferences such as power interference, electrode polarization interference, myoelectricity interference, baseline drift, apparatus buzz and so on in electrocardiosignal acquisition system. It is very difficult to effectively remove these interferences in the process of actual measurement. Methods Power harmonic interference, electrode polarization interference and myoelectricity interference were removed by low-pass filter. Baseline drift was removed by high-pass filter. Power basic frequency interference was removed by 50 Hz trap filter. Results These three design proposals had such advantages as good effect, rapid speed and easy realization. Conclusion They can be well applied in ECG monitor with embedded CPU and real time character. Besides, they can also be used in medical apparatus measuring other biological electric signals and industrial observation and control system.

SELECTION OF CITATIONS
SEARCH DETAIL